MRC 8000 Recorder / Controller
|
Quick Specs...
- 2 large displays - Allows you to see critical process values at the same time.
- 12 inch chart offering high resolution of recorder process variables.
- Easy to use - All programming done from a simple keypad.
- Reliability - Maintenance free recording for years to come.
|
|
|
|
Overview / Design Principle:
The MRC 8000 incorporates numerous refinements over its 10½ MRC 7000™ sibling, including a larger 12 inch recording area; an advanced platen assembly which eliminates slide wire feedback for improved reliability; as well as the incorporation of optional isolated 4–20mA outputs to provide the highest resolution and accuracy available in a recorder of this type. The MRC 8000 is offered in two versions: a basic recorder and a recording controller. Both may be specified as either single pen or dual pen units. Each version is capable of measuring, recording and displaying temperature, pressure, level, flow and other process variables. The MRC 8000 includes isolated universal inputs and a list of optional capabilities including: transmitter power supply, 5A relay outputs, auxiliary inputs for remote setpoints, RS-485 communications, door lock and NEMA 4X enclosure.
Features and Benefits:
- 12½ Micro-based recording controller with remote setpoint capability
- Two large displays—allow you to see critical process values at the same time on 2 pen models
- Easy, straightforward programming—allows you to configure your recorder with a logical step-by-step process using a simple keypad
- High resolution of recorder process variables for better record accuracy
- Reliability—maintenance free recording for years to come
|
|
|
Applications:
- Process Validation
- Trend Analysis
- Regulatory Compliance
- Product Safety:
- Temperature
- Pressure
- pH Level
- Flow
Industries:
Oven, chamber, furnaces, heat treating, food processing, harsh water environments
|
|
| Modes: |
Digital; record or controller functionality. |
| Display: |
Two 4-digit digital displays: 0.56½ high, red, seven segment LED; 3 button keypad; automatic and decimal point positioning. |
| Status Indicators: |
Red LEDs for ALRM1/ALRM2 (Recorders); yellow, red LEDs MAN, OUT1/OUT2, ALRM. |
| Chart: |
10½ circular chart; 100 charts furnished with each instrument. Unless otherwise specified, charts shipped with instrument are 0–100 range. 24 hour rotation default setting. |
| Chart Drive: |
DC Stepper Motor. |
| Chart Rotation: |
User configurable from 0.1 and 999.9 hours per revolution. |
| Chart Range: |
Bottom and top of span –9999 to 9999 units. |
| Pen Type: |
One or two disposable fiber tip pen. |
| Pen Color: |
Pen 1 (red); Pen 2 (green). |
| Memory Backup: |
Battery backed SRAM; 5 year minimum life. |
| Construction/Enclosure: |
Gasketed cover, case and windows. Structural foam case and cover with plastic or glass window area. |
| Operating Temp: |
32° to 122°F (0° to 50°C). |
| Storage Temp: |
–40° to 149°F (–40° to 65°C). |
| Humidity: |
0% to 90% non-condensing R.H. |
| Vibration: |
0.5 to 100Hz @ 0.2g. |
| Power Consumption: |
25VA max. |
| Line Voltage: |
115V or 230VAC ±10%, 50–60Hz. |
| Thermocouple: |
J, K, T, R, S, E, B, N, C. |
| RTD: |
100 ohm, platinum; 0.00385 ohms/ohm/°C |
| RTD Excitation Current: |
330 microamps, typical. |
| DC Voltage: |
0–25mV, 0–50mV, 10–50mV, 0–5V, 1–5V. |
| DC Current: |
4–20mA or 0–20mA used with appropriate external shunt resistor. |
| Remote Setpoint Input: |
0–5VDC, 1–5VDC, 4–20mA, or 0–20mA with shunt resistor. |
| Control Outputs |
| ON/OFF: |
Assignable to alarm and control outputs. |
| Relay: |
SPDT; 115VAC 5.0A resistive, 1/8HP, 230VAC, 230VAC 2.5A resistive, 1/8HP, 250VA. |
| SSR Driver: |
Open collector output; short circuit protected @ 100mA max; provides 4VDC @ 20mA or 3VDC @ 40mA. |
| Current: |
Assignable to process value or setpoint transmission or control outputs; 0–20mA or 4–20mA nominal output span; 650 ohm |
| Alarm/Event Outputs (options) |
| Number: |
Up to two process alarms for each of two inputs. Type: Process high/low (recorder); process, deviation and band (controller). |
| Relay: |
SPDT: 115VAC 5.0A resistive, 1/8HP, 230VAC; 230VAC 2.5A resistive, 1/8HP, 250VA. |
| SSR Driver: |
Open collector output; short circuit protected @ 100mA max; provides 4VDC @ 20mA or 3VDC @ 40mA. |
| Process Alarm: |
Direct (High) or Reverse (Low) –9999 to 9999 units. |
| Deviation Alarm: |
Direct (deviation above setpoint) or Reverse (deviation below setpoint) –3000 to 3000 units. |
| Deviation Band Alarm: |
Open or closed 1 to 3000 units. |
| Alarm Hysteresis: |
0–300 units. |
| General |
| Input Measurement Error: |
Type J, K, T, E, N, C, T/C and RTD ±0.25% of reading plus 1 degree @ 25°C; Type R, S, B, C, T/C |
| Ambient Temperature Error: |
0.04% of span per degree C deviation from 25°C. |
| Cold Junction Compensation Error: |
±0.2% @ 25°C. |
| Cold Junction Compensation Rejection: |
0.04% deviation from 25°C. |
| Linearization Error: |
TCs: ±0.25°C typical; ±0.5°C worst case with exceptions;
RTDs: ±0.1°C typical; ±0.3°C worst case. |
| Noise Rejection: |
Common Mode Rejection: 90dB minimum; 24VAC maximum for RTD input; 115VAC max for other inputs;
Normal Mode Rejection: 85dB minimum @ 60Hz or greater.
|
| Isolation: |
N/A. |
| Chart Accuracy: |
Recording: 0.5% of span. |
| Chart Rotation: |
±0.5% or rotation time.. |
| Chart Accuracy: |
Recording: 0.5% of span. |
| Chart Rotation: |
±0.5% or rotation time. |
| Resolution: |
0.15% of chart span. |
| Dead Band: |
0.3% of chart span. |
| Process Value Output Error Limit: |
N/A. |
| Record Error Limit: |
N/A. |
| Control Parameters |
| Proportional Band Output 1/Output 2: |
1 to 3000 units. |
| Manual Reset (Integral): |
–1500 to 1500 units. |
| Auto Reset (Integral): |
0–100 repeats/minute. |
| Rate Derivative: |
0–10 minutes. |
| Cycle Time Output 1/Output 2: |
1–240 seconds. |
| Position Proportioning Sensitivity: |
0.0–50.0%. |
| ON/OFF Hysteresis: |
0–300 units (width of hysteresis band). |
| First /Second Output Position: |
–1000 to 1000 units. |
| Control Action: |
Direct or reverse. |
| Automatic Transfer Function: |
User-selectable to transfer from manual to automatic control when setpoint is reached; can be disabled. |
| Anti-Reset Windup: |
Auto-reset is disabled when the process is outside of the proportional band. |
| Auto/Manual: |
Bumpless transfer. |
| Manual Output: |
0–100%. |
| Output Limiting: |
High/Low 0–100%. |
| Setpoint Limiting: |
High/Low limit: –9999 to 9999 units. |
| Communications Port: |
RS–485 serial, half duplex. |
| Protocol: |
Per ASCII and ANSI X3.28 subcategories 2.5 & A4. |
| Bit Rate: |
User configurable; 300, 600, 1200, 2400, 4800 or 9600/sec. |
| Configuration: |
Monitor: Read only.
Normal: Read and write. |
| Safety: |
UL 1092/916 and QUXY File E67237; CSA Spec 142 File E67237; CE EN60010–1 1993/1995. |
| Immunity: |
CE EN50082-1:1992 |
| Emissions: |
CE EN55022:1987 Class A. |
| Limit Device: |
N/A |
| Other: |
ISO 9002 registered. |
| NEMA 3 standard; NEMA 4 optional; CE compliance optional. |
| Width: |
14.12" (359mm). |
| Depth: |
7.75" (197mm). |
| Height: |
16.77" (426mm). |
| Weight: |
20 lbs (9.1kg). |
| Mounting/Mounting Position: |
Panel or wall. |
- Plastic or glass window option.
- 24V DC transmitter power supply option.
- Door lock option.
- NEMA 4 protection option; CE compliance option.
- 5A relay output option.
- Remote setpoint/position proportioning option.
- RS-485 communication option.
- 115 or 230VAC input option.
- Door lock and sealed conduit/connector option.
|
|
|
Available Specifications: