Partlow Homepage - Temperature Recorder & Indicator Products Home   |   DICG website   |    View Order   |   Site Map
Temperature Controller and Temperature Validation...Made Simple
 
 
  
RFH15-79/15-15 Dual Recording Temperature Control
  

RFH15-79/15-15 Dual Recording Temperature Control

 
 

Quick Specs...

  • A two pen, 10" circular chart, temperature recording controller with four switches, providing dual on-off control for heat-cool applications on each pen or heat-cool-humidity applications.
  • Available with 12, 24, or 48 hour, or 7 day rotation times for 125VAC, 60 Hz operation, and others.
  • Seventeen operating ranges covering -30ºF to 1100ºF.
  • Can be panel or surface mounted.



Buy Online

Printer-friendly Version

Dimensional Diagrams

Product Configurator

 

Overview Industry/Application Specifications Related Info  

Overview / Design Principle:

This dual instrument controls and records two temperature variables on a single chart. It is ideal for temperature and humidity controlled applications such as growth chambers, smokehouses and kilns. The unit is made up of two switch mechanisms. UL and CSA listed. Flush or wall mount available (brackets supplied).

Operation:

The unit is a mechanical, recording controller that incorporates two independent control switching systems in a single case. To avoid interference, the two pens register a difference on one-twelth revolution of the chart, or a two hour differential on a 24 hour chart. Control points are indicated by a red setting pointer on the right hand mechanism, a green pointer on the left.

There are two control switches mounted on each mechanism, they are mounted one behind the other. First switch to be actuated on a termperature rise is the leaf-type switch. The second switch (a pin type for left mechanism and a leaf type for the right mechanism) is actuated when the recorded temperature exceeds the operation of the first switch. Temperature actuation points between teh two switches (differential) is adjustable from 0 to 5% of scale range, with tolerance on switch setting ± 1/2%, adjustment is made by set screws inside the instrument case.

Applications:

Basic recording capability for diverse industrial heat and cooling applications

Industries:

  • Mobile Refridgeration
Standard Features
Chart Diameter: 10"
Chart Marking: Felt Tip Cartridge.
Chart Drive: Electric with toggle switch, or spring wound.
Chart Rotation Periods: 24 and 48 hour, 7 day, other options.
Flush Mount Cutout: 13-1/2" W x 12-5/8" H
Surface Mounting: Mounting brackets included
Electrical Hookup: Terminal block accessible with cover open.
Switch Type: Three wire SPDT, 2 per each mechanism.
Switch Sensitivities: Normal 1% of range (#79) standard.
Super Sensitive (#73) 0.5% or range-field installable.
Conduit Openings: One 7/8" diameter hole on each side of the case for 1/2" conduit fitting; drill guide hole spotted in the rear of the case showing optional rear opening location.
Electrical Rating: 50VA, inductive; 500VA, non inductive; 250V maximum AC only.

Physical Characteristics
Dimensions: 15-1/8" W x 13-3/16" H x 4-7/8" D
Approx. Net Weight: 9 lbs
Approx. Ship Weight: 14 lbs

Ratings / Agency Approvals
UL and CSA

Warranty
1 year